{"id":15446,"date":"2026-11-16T13:27:17","date_gmt":"2026-11-16T13:27:17","guid":{"rendered":"https:\/\/blog.geostru.eu\/mdc-retaining-walls-buttresses-design\/"},"modified":"2026-11-16T13:27:17","modified_gmt":"2026-11-16T13:27:17","slug":"mdc-retaining-walls-buttresses-design","status":"publish","type":"post","link":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/","title":{"rendered":"MDC: walls with buttresses are now designed as structural members"},"content":{"rendered":"<p>In the new version of <strong>MDC \u2013 Retaining walls<\/strong>, walls with external buttresses are no longer just geometry: the buttress is designed as a structural member, with its own internal forces, checks and reinforcement.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\" alt=\"MDC 3D view: wall with external buttresses and reinforcement\" width=\"1130\" height=\"680\" \/><figcaption>MDC 3D view: wall with external buttresses and reinforcement<\/figcaption><\/figure>\n<h2>The buttress as an inverted T-shaped cantilever<\/h2>\n<p>Each external buttress, together with the collaborating part of the stem, is checked as an <strong>inverted T-shaped cantilever<\/strong> loaded by the actions of one spacing. Section by section the program checks bending with axial force, shear in the web, longitudinal shear between flange and web, buckling of the compressed free edge and, at the serviceability limit state, stresses and crack widths.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-prospetto.jpg\" alt=\"Dimensioned downstream elevation of the wall with buttresses\" width=\"1040\" height=\"590\" \/><figcaption>Dimensioned downstream elevation of the wall with buttresses<\/figcaption><\/figure>\n<h2>The stem between two buttresses as a plate<\/h2>\n<p>Between two buttresses the stem bends both vertically and horizontally. MDC analyses it as a <strong>finite element plate<\/strong>, fixed at the base and on the buttresses and free at the top, loaded with the earth pressure of the combination (soil, surcharges, water table and earthquake). The plate moments give the horizontal and vertical reinforcement of the stem.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-contrafforte-armature.jpg\" alt=\"Buttress reinforcement designed by MDC, with the minimum safety factors\" width=\"1150\" height=\"780\" \/><figcaption>Buttress reinforcement designed by MDC, with the minimum safety factors<\/figcaption><\/figure>\n<h2>Reinforcement designed by the program<\/h2>\n<p>The buttress reinforcement, i.e. the bars along the inclined edge and the web stirrups, is <strong>designed by MDC<\/strong> and appears in the drawing, in the bar schedule and in the calculation report, together with the <strong>minimum safety factors<\/strong> of the checks.<\/p>\n<h2>New views<\/h2>\n<ul>\n<li><strong>Dimensioned downstream elevation<\/strong> with buttresses and piles: if the buttresses do not fall above the piles, the program warns you and suggests the value that lines them up.<\/li>\n<li><strong>Stress map of the stem<\/strong> between two buttresses (blue compression, red tension) for the selected combination.<\/li>\n<li><strong>3D view<\/strong> with wall, buttresses, reinforcement, soil layers and piles.<\/li>\n<\/ul>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-paramento-tensioni-piastra.jpg\" alt=\"Stress map of the stem between two buttresses, analysed as a FEM plate\" width=\"1600\" height=\"1000\" \/><figcaption>Stress map of the stem between two buttresses, analysed as a FEM plate<\/figcaption><\/figure>\n<p>To try the method right away, the welcome screen offers the new example <strong>&#8220;Wall with buttresses&#8221;<\/strong>: a 30 m long wall on piles.<\/p>\n<p><strong>Existing projects.<\/strong> The new method replaces the equivalent-thickness method used so far: projects with buttresses are recalculated, and the stem reinforcement and the checks may differ from past results. Internal buttresses (upstream side) are still taken into account for their weight, but not as resisting members.<\/p>\n<p>The method in detail is in the manual: <a href=\"https:\/\/help.geostru.io\/mdc\/en\/Contrafforti_calcolo\/\">MDC \u2013 Buttress design<\/a>. The program: <a href=\"https:\/\/www.geostru.eu\/en\/shop\/software-en\/geotechnical-software\/retaining-walls-software-mdc\/\">MDC \u2013 Retaining walls<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the new version of MDC \u2013 Retaining walls, walls with external buttresses are no longer just geometry: the buttress is designed as a structural member, with its own internal forces, checks and reinforcement. MDC 3D view: wall with external buttresses and reinforcement The buttress as an inverted T-shaped cantilever Each external buttress, together with&hellip;<\/p>\n","protected":false},"author":16658,"featured_media":15441,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[2773,2177,2180],"class_list":["post-15446","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","tag-buttresses","tag-mdc-en","tag-retaining-walls","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v25.0) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Buttressed retaining walls in MDC: T-cantilever and FEM plate<\/title>\n<meta name=\"description\" content=\"In the new version of MDC, external buttresses are checked as T-shaped cantilevers and the stem between two buttresses as a finite element plate.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MDC: walls with buttresses are now designed as structural members\" \/>\n<meta property=\"og:description\" content=\"In the new version of MDC \u2013 Retaining walls, walls with external buttresses are no longer just geometry: the buttress is designed as a structural member,\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\" \/>\n<meta property=\"og:site_name\" content=\"Geostru Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GeoStruSoftware\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T13:27:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1130\" \/>\n\t<meta property=\"og:image:height\" content=\"680\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sc (non attivo)\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sc (non attivo)\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\"},\"author\":{\"name\":\"sc (non attivo)\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/e065ac1a7b26936e8df7096ec39b166f\"},\"headline\":\"MDC: walls with buttresses are now designed as structural members\",\"datePublished\":\"2026-11-16T13:27:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\"},\"wordCount\":403,\"publisher\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\",\"keywords\":[\"buttresses\",\"MDC\",\"retaining walls\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\",\"url\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\",\"name\":\"Buttressed retaining walls in MDC: T-cantilever and FEM plate\",\"isPartOf\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\",\"datePublished\":\"2026-11-16T13:27:17+00:00\",\"description\":\"In the new version of MDC, external buttresses are checked as T-shaped cantilevers and the stem between two buttresses as a finite element plate.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage\",\"url\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\",\"contentUrl\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg\",\"width\":1130,\"height\":680},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.geostru.eu\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"MDC: walls with buttresses are now designed as structural members\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#website\",\"url\":\"https:\/\/blog.geostru.eu\/en\/\",\"name\":\"Geostru Blog\",\"description\":\"GeoStru Blog\",\"publisher\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.geostru.eu\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#organization\",\"name\":\"Geostru\",\"url\":\"https:\/\/blog.geostru.eu\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2020\/05\/geostru_website_logo_24.png\",\"contentUrl\":\"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2020\/05\/geostru_website_logo_24.png\",\"width\":75,\"height\":24,\"caption\":\"Geostru\"},\"image\":{\"@id\":\"https:\/\/blog.geostru.eu\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/GeoStruSoftware\/\",\"https:\/\/www.instagram.com\/geostru\/\",\"https:\/\/www.linkedin.com\/in\/geostru-software-146a3646\/\",\"https:\/\/youtube.com\/user\/geostru\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/e065ac1a7b26936e8df7096ec39b166f\",\"name\":\"sc (non attivo)\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/b7bd7043390f6b895db5dd048c11aeea?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/b7bd7043390f6b895db5dd048c11aeea?s=96&d=mm&r=g\",\"caption\":\"sc (non attivo)\"},\"url\":\"https:\/\/blog.geostru.eu\/en\/author\/castagnino-sebastiano\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Buttressed retaining walls in MDC: T-cantilever and FEM plate","description":"In the new version of MDC, external buttresses are checked as T-shaped cantilevers and the stem between two buttresses as a finite element plate.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/","og_locale":"en_US","og_type":"article","og_title":"MDC: walls with buttresses are now designed as structural members","og_description":"In the new version of MDC \u2013 Retaining walls, walls with external buttresses are no longer just geometry: the buttress is designed as a structural member,","og_url":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/","og_site_name":"Geostru Blog","article_publisher":"https:\/\/www.facebook.com\/GeoStruSoftware\/","article_published_time":"2026-11-16T13:27:17+00:00","og_image":[{"width":1130,"height":680,"url":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg","type":"image\/jpeg"}],"author":"sc (non attivo)","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sc (non attivo)","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#article","isPartOf":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/"},"author":{"name":"sc (non attivo)","@id":"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/e065ac1a7b26936e8df7096ec39b166f"},"headline":"MDC: walls with buttresses are now designed as structural members","datePublished":"2026-11-16T13:27:17+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/"},"wordCount":403,"publisher":{"@id":"https:\/\/blog.geostru.eu\/en\/#organization"},"image":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg","keywords":["buttresses","MDC","retaining walls"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/","url":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/","name":"Buttressed retaining walls in MDC: T-cantilever and FEM plate","isPartOf":{"@id":"https:\/\/blog.geostru.eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage"},"image":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg","datePublished":"2026-11-16T13:27:17+00:00","description":"In the new version of MDC, external buttresses are checked as T-shaped cantilevers and the stem between two buttresses as a finite element plate.","breadcrumb":{"@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#primaryimage","url":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg","contentUrl":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2026\/11\/mdc-muro-contrafforti-vista-3d.jpg","width":1130,"height":680},{"@type":"BreadcrumbList","@id":"https:\/\/blog.geostru.eu\/en\/mdc-retaining-walls-buttresses-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.geostru.eu\/en\/"},{"@type":"ListItem","position":2,"name":"MDC: walls with buttresses are now designed as structural members"}]},{"@type":"WebSite","@id":"https:\/\/blog.geostru.eu\/en\/#website","url":"https:\/\/blog.geostru.eu\/en\/","name":"Geostru Blog","description":"GeoStru Blog","publisher":{"@id":"https:\/\/blog.geostru.eu\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.geostru.eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.geostru.eu\/en\/#organization","name":"Geostru","url":"https:\/\/blog.geostru.eu\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.geostru.eu\/en\/#\/schema\/logo\/image\/","url":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2020\/05\/geostru_website_logo_24.png","contentUrl":"https:\/\/blog.geostru.eu\/wp-content\/uploads\/sites\/9\/2020\/05\/geostru_website_logo_24.png","width":75,"height":24,"caption":"Geostru"},"image":{"@id":"https:\/\/blog.geostru.eu\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GeoStruSoftware\/","https:\/\/www.instagram.com\/geostru\/","https:\/\/www.linkedin.com\/in\/geostru-software-146a3646\/","https:\/\/youtube.com\/user\/geostru"]},{"@type":"Person","@id":"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/e065ac1a7b26936e8df7096ec39b166f","name":"sc (non attivo)","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.geostru.eu\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/b7bd7043390f6b895db5dd048c11aeea?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b7bd7043390f6b895db5dd048c11aeea?s=96&d=mm&r=g","caption":"sc (non attivo)"},"url":"https:\/\/blog.geostru.eu\/en\/author\/castagnino-sebastiano\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/posts\/15446"}],"collection":[{"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/users\/16658"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/comments?post=15446"}],"version-history":[{"count":0,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/posts\/15446\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/media\/15441"}],"wp:attachment":[{"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/media?parent=15446"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/categories?post=15446"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.geostru.eu\/en\/wp-json\/wp\/v2\/tags?post=15446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}